In electric motors, power today is given in kilowatts (kW), while horsepower (HP) is an older unit of power. The conversion between them rests on a fixed factor: 1 HP ≈ 0.746 kW, that is kW = HP × 0.746 and, the other way round, HP = kW ÷ 0.746. This article gives the kW–HP equivalents for the whole power range (from 0.75 kW up to 315 kW), the difference between the two units, and how to use the conversion in practice.
DRG Motor is a manufacturer, supplier and seller of electric motors. Once you have used the conversion table below to find the power closest to your need, you can study the models by power and speed in the online motor shop and see the same products grouped in the three-phase asynchronous electric motors category.
kW vs HP: a power unit or an old unit?
kW (kilowatt) belongs to the International System of Units (SI) and directly expresses the rated power a motor draws and delivers to its shaft. Modern motor nameplates always state rated power in kW. HP (horsepower) is a unit long used in industry; today it survives mostly out of habit and from older machine documents.
One small but useful detail: two kinds of "horsepower" circulate. The Anglo-Saxon mechanical HP is about 0.746 kW, while the metric horsepower (PS) used in continental Europe is about 0.735 kW. Motor catalogues and this table use the widely accepted value of 1 HP = 0.746 kW; as the gap between the two definitions is about 1.5%, the result does not change on standard power steps.
kW–HP conversion table (0.75 – 315 kW)
The table below gives the horsepower equivalent of the IEC standard power steps. The values come from HP = kW ÷ 0.746 and are rounded to the nearest horsepower figure established in the industry. The last column shows the housing material option in the DRG range for that class (aluminium 0.25–11 kW, cast iron from 0.55 kW upward).
| Power (kW) | Approx. horsepower (HP) | DRG housing option |
|---|---|---|
| 0.75 kW | ≈ 1 HP | aluminium / cast iron |
| 1.1 kW | ≈ 1.5 HP | aluminium / cast iron |
| 1.5 kW | ≈ 2 HP | aluminium / cast iron |
| 2.2 kW | ≈ 3 HP | aluminium / cast iron |
| 3 kW | ≈ 4 HP | aluminium / cast iron |
| 4 kW | ≈ 5.5 HP | aluminium / cast iron |
| 5.5 kW | ≈ 7.5 HP | aluminium / cast iron |
| 7.5 kW | ≈ 10 HP | aluminium / cast iron |
| 11 kW | ≈ 15 HP | aluminium / cast iron |
| 15 kW | ≈ 20 HP | cast iron |
| 18.5 kW | ≈ 25 HP | cast iron |
| 22 kW | ≈ 30 HP | cast iron |
| 30 kW | ≈ 40 HP | cast iron |
| 37 kW | ≈ 50 HP | cast iron |
| 45 kW | ≈ 60 HP | cast iron |
| 55 kW | ≈ 75 HP | cast iron |
| 75 kW | ≈ 100 HP | cast iron |
| 90 kW | ≈ 125 HP | cast iron |
| 110 kW | ≈ 150 HP | cast iron |
| 132 kW | ≈ 180 HP | cast iron |
| 160 kW | ≈ 220 HP | cast iron |
| 200 kW | ≈ 270 HP | cast iron |
| 250 kW | ≈ 340 HP | cast iron |
| 315 kW | ≈ 430 HP | cast iron |
As the table shows, 0.75 kW is about 1 HP, 7.5 kW about 10 HP, 75 kW about 100 HP and 315 kW about 430 HP. The figures are approximate; a motor's real power is always the rated value in kW printed on its nameplate.
Click to see current electric motor prices and order nowSEE PRICES →
How to convert a request given in horsepower to kW
If you only have a horsepower figure (for example "I need a 15 HP motor"), multiply it by 0.746: 15 × 0.746 ≈ 11.2 kW. Round the intermediate figure to the nearest standard kW step; here that is 11 kW. In the other direction, if your motor is 22 kW then 22 ÷ 0.746 ≈ 29.5 HP, which the industry calls 30 HP.
A practical rule: when a request given in HP converts to an in-between kW value, choosing the next standard step up is the safe side, leaving a little margin for short load peaks. If you would rather not do the maths by hand, enter the power into the electric motor calculator to also see speed and torque, and check the drawn current with the motor current chart.
A mid-power example: 4 – 11 kW DRG three-phase models
It helps to show the kW–HP match with concrete models in the most commonly requested mid-power band. The table below lists several 1500 rpm (4-pole) aluminium DRG models with both their kW and approximate HP value and their rated current at 400 V; the model codes link straight to the product page. The voltage at these powers is 400/690 V (Δ/Y).
| Model | Power (kW ≈ HP) | Speed | Rated current (400 V) |
|---|---|---|---|
| DRG-112M-4-AL | 4.0 kW ≈ 5.5 HP | 1500 rpm | 7.95 A |
| DRG-132S-4-AL | 5.5 kW ≈ 7.5 HP | 1500 rpm | 10.7 A |
| DRG-112M-4K-AL (compact) | 5.5 kW ≈ 7.5 HP | 1500 rpm | 10.7 A |
| DRG-132M-4-AL | 7.5 kW ≈ 10 HP | 1500 rpm | 14.3 A |
| DRG-160M-4-AL | 11.0 kW ≈ 15 HP | 1500 rpm | 20.4 A |
| DRG-132M-4K-AL (compact) | 11.0 kW ≈ 15 HP | 1500 rpm | 20.4 A |
The same power may come in different frame sizes and compact versions; for instance 5.5 kW (≈ 7.5 HP) exists both in the standard 132S and the compact 112M-4K frame. The horsepower equivalent is identical in both, because HP is merely another way of stating the power; what changes is the shaft and frame dimensions.
Common mistakes when converting
- Rounding horsepower "roughly" on its own: like thinking 10 HP is 7 kW. In fact 10 × 0.746 ≈ 7.46 kW, i.e. the standard 7.5 kW.
- Mixing metric and mechanical horsepower: a small difference, but in precise work know which definition you use; for motor selection 0.746 is enough.
- Looking only at power and skipping speed: a 7.5 kW motor gives very different speed and torque in 2, 4 or 6 poles. Even if the HP is the same, choose the speed that suits the application.
- Looking for a non-standard value: figures like "1 kW" or the "exact equivalent of 10 HP" are not separate steps in the catalogue; move to the nearest standard power.
Weigh power together with speed and torque
The kW–HP conversion only carries power from one unit to another; what decides whether the motor does the job is the trio of power, speed and torque. Torque is approximately T = 9550 · P / n (P in kW, n in rpm). At the same kW, torque rises as speed falls; that is why, of two motors with equal horsepower, the 1000 rpm one gives noticeably more torque than the 3000 rpm one. If you are replacing an existing motor, base your choice on the kW, speed and connection data on its nameplate.
Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp
Once you have the right kW–HP match, you can compare all power, speed and housing options through the shop.
See the three-phase asynchronous motor models closest to the kW or HP figure you need, with current prices, in the shopSEE PRICES
Frequently asked questions
How many kW is 1 HP?
1 HP is about 0.746 kW. As a standard product step this rounds to 0.75 kW. In the other direction, 1 kW is about 1.34 HP.
Is there a difference between metric horsepower (PS) and HP?
Yes, a small one: mechanical HP ≈ 0.746 kW, metric horsepower (PS) ≈ 0.735 kW. Motor selection uses the widely accepted 0.746 value and the result does not change on standard steps.
Is a motor's real power kW or HP?
A motor's rated power is stated on the nameplate in kW and that is the binding value. HP is simply the same power in an older unit; base your purchase decision on the kW figure.
How do I match an order given in horsepower?
Multiply the HP figure by 0.746, round to the nearest standard kW step, then choose the speed (pole count) that suits the application at that power. The table above and the calculator make this matching easy.
Electric Motors Related to This Topic — Models and Current Prices
Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.
4 kW Three-Phase Motor 1500 rpm – DRG-112M-4 Aluminium
- 4 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 112M
- Shaft: 28 × 60 mm
5.5 kW Three-Phase Motor 1500 rpm – DRG-132S-4 Aluminium
- 5.5 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 132S
- Shaft: 38 × 80 mm
5.5 kW Compact Three-Phase Motor 1500 rpm – DRG-112M-4K Aluminium
- 5.5 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 112M
- Shaft: 28 × 60 mm
7.5 kW Three-Phase Motor 1500 rpm – DRG-132M-4 Aluminium
- 7.5 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 132M
- Shaft: 38 × 80 mm
11 kW Three-Phase Motor 1500 rpm – DRG-160M-4 Aluminium
- 11 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 160M
- Shaft: 42 × 110 mm
11 kW Compact Three-Phase Motor 1500 rpm – DRG-132M-4K Aluminium
- 11 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 132M
- Shaft: 38 × 80 mm