A 90 kW three-phase asynchronous electric motor is available from DRG in three speed options: 3000 rpm (2 poles), 1500 rpm (4 poles) and 1000 rpm (6 poles). All three have a cast-iron frame, a 400/690 V connection, and rated currents at 400 V between 152 and 161 A. Below you will find the current, shaft and torque figures of these three models line by line.

Grey cast-iron 90 kW DRG three-phase asynchronous electric motor

DRG Motor is a manufacturer, supplier and seller of electric motors. It is based in İzmir and ships quickly across all of Türkiye, that province included. You can review the models in this power class by speed and frame in the online electric motor shop, and see all of these products together in the three-phase asynchronous electric motors category.

Where 90 kW comes into play

This power class is no longer small-workshop territory; it belongs to the production line. In the field we most often see 90 kW on large screw compressors, high-flow centrifugal and axial fans, crushing and screening plants, cement and mining mills, heavy conveyor drives, and large submersible and centrifugal pumps. What they share is long, heavily loaded running. That is exactly why, at the 90 kW class, the frame material and the right speed choice matter as much as the kW on the plate.

One example: the same 90 kW demands high torque at 1000 rpm in a crusher, but high flow at 3000 rpm in a ventilation fan. Same power, very different job. So we discuss the machine's speed first, then the motor's pole count.

Speed, frame and 400 V current

Here is the identity line of the three 90 kW models. As the pole count rises, speed falls and torque grows; the frame size grows with it. Each code links straight to its product page.

ModelSpeed / PolesFrame (IEC)Current (400 V)
DRG-280M-23000 rpm · 2 poles280M · cast iron152 A
DRG-280M-41500 rpm · 4 poles280M · cast iron155 A
DRG-315M-61000 rpm · 6 poles315M · cast iron161 A

Note: the 2- and 4-pole models sit on a 280M frame, while the 6-pole model, delivering the same power at a lower speed, steps up one size to a 315M frame. So a plant wanting 90 kW at 1000 rpm must plan both the physical space and the coupling axis around the 315M frame.

Click to see current electric motor prices and order nowSEE PRICES →

Above 150 amps: cable and protection

At 90 kW the 400 V rated current sits in the 152–161 A band. This is the level where cable sizing must be taken seriously. Choose the cable cross-section by its length, laying method and ambient temperature; as a first pass the motor cable size calculator and motor current chart help. Size the thermal protection and contactor from this rated current too, and set the exact value per the motor plate and panel documentation. Before working on the panel, cut the power, confirm it is de-energised, and have the work done by authorised electrical personnel.

Shaft, torque and connection

Torque comes from power divided by speed: T = 9550 × P(kW) / n(rpm). With 90 kW fixed, torque grows as speed falls, and the shaft diameter thickens accordingly.

ModelSpeedRated torqueShaft (D×E)
DRG-280M-23000 rpm≈ 286 Nm65x140 mm
DRG-280M-41500 rpm≈ 573 Nm75x140 mm
DRG-315M-61000 rpm≈ 860 Nm85x170 mm

The difference is plain: a shaft at 286 Nm at 3000 rpm climbs to 860 Nm at 1000 rpm, and the shaft diameter thickens from 65 mm to 85 mm. Choose the coupling, pulley and bearings around this shaft size. The voltage is 400/690 V (Δ/Y) on all three; on a 400 V grid the winding is connected in delta.

Why a cast-iron frame?

DRG offers 90 kW only in a cast-iron frame, and there is a technical reason. An aluminium frame is light and useful at small ratings, but in this class vibration, mechanical shock and heat load all rise. Cast iron, with its rigid body, damps vibration better, keeps the bearing housings in line, and withstands the knocks of a heavy-industry environment. For a 90 kW electric motor running beside a crusher, under a mill or on an outdoor fan, a cast-iron frame is not a preference but a requirement.

The starting question at 90 kW

Starting a motor of this size direct-on-line draws a high inrush current and strains both the panel and the grid. In practice, three methods are used at the 90 kW class to limit inrush: star-delta starting (the 400/690 V winding suits this), a soft starter, or a variable frequency drive. Which one fits depends on the machine's starting torque and whether speed control is needed. For variable-flow duties such as fans and pumps a drive stands out; for high-inertia crushers a staged start does.

Settling the pole count, frame and starting method together at the selection stage saves a panel revision later.

Choosing the right 90 kW model

The short of it: set the speed from the machine (2/4/6 poles), read the current and torque from the table above, and confirm the frame (280M or 315M) against your layout. Where you are unsure, share the plate of the existing machine or old motor and we will pin down the suitable DRG model together. You can see every option in the online electric motor shop and make a quick pre-selection by entering power and speed in the electric motor calculator.

Frequently asked questions

How many HP is 90 kW?

90 kW corresponds to roughly 125 HP (1 HP ≈ 0.746 kW). The plate usually shows both the kW and the HP equivalent.

Which frame comes with a 90 kW motor?

The 2- and 4-pole 90 kW models come on a 280M frame, while the 6-pole model is on a 315M frame. The same power at a lower speed needs one frame size larger.

Can 90 kW be started direct-on-line?

Technically possible, but the inrush current is high at this power; star-delta, a soft starter or a frequency drive is usually preferred. The right method depends on the machine's starting load.

Should I connect at 400 V or 690 V?

All three models are wound 400/690 V (Δ/Y). On the 400 V grid they connect in delta (Δ); a 690 V line corresponds to the star (Y) connection.

See the current price of the 90 kW three-phase electric motor that fits your need in the shop.SEE PRICES

Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp

Electric Motors Related to This Topic — Models and Current Prices

Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.

ALL MODELS AND DETAILS IN THE ONLINE SHOP →