A 132 kW three-phase asynchronous electric motor sits at the top of the DRG range. Depending on the pole count it runs at 3000, 1500 or 1000 rpm, draws roughly 222–232 A on a 400 V supply and comes with a 315 cast-iron frame. It is about 180 HP, and the winding is 400/690 V (Δ/Y) at every speed.

Grey cast-iron 315-frame DRG 132 kW three-phase asynchronous electric motor

DRG Motor is a manufacturer, supplier and seller of electric motors. It is based in İzmir and ships quickly across all of Türkiye, that province included. To compare the three 132 kW models by speed, current and shaft size, visit the online electric motor shop; to see these ratings together, browse the three-phase asynchronous electric motors category.

Where does 132 kW work?

At this rating the electric motor is a plant backbone. In the field we see 132 kW mostly on high-flow process pumps, large screw and piston compressors, cement and mining mills, heavy crushers, big extractor and stack fans, and long heavy-duty conveyors. Because a single stopped motor halts a whole line, selection and spares are taken seriously in this class.

Pole choice sets the character: 2 poles (3000 rpm) for high-speed compressors and centrifugal pumps, 4 poles (1500 rpm) for general drive and gearboxes, 6 poles (1000 rpm) for slow, very high-torque mills, crushers and mixers. The same 132 kW label suits three very different machines.

One power, three speeds: 315 frame and torque

As the pole count changes, both speed and shaft torque change. The slower it turns, the higher the torque for the same power. The values below are for 50 Hz synchronous speed; the loaded speed on the plate is slightly lower because of slip.

PolesSpeed (rpm)Current (400 V)Approx. torque
2 poles3000222 A~420 Nm
4 poles1500224 A~840 Nm
6 poles1000232 A~1261 Nm

Torque figures are approximate, from T=9550·P/n; use the product page for exact shaft torque. The 2- and 4-pole models are 315M, the 1000 rpm model is a 315L frame.

Click to see current electric motor prices and order nowSEE PRICES →

400/690 V and starting at this rating

At 132 kW the winding is 400/690 V (Δ/Y), not 230/400 V. The first value is delta (Δ), the second star (Y). A 132 kW motor marked 400/690 V runs at full power in delta on a 400 V grid; the 690 V value is for higher-voltage lines.

Direct-on-line starting is not realistic here. Started directly, a 132 kW electric motor pulls several times its rated current, causing serious voltage dip, mechanical shock and tripped protection. A soft starter or a drive is therefore standard in most panels at this rating; star-delta is only used for light-starting loads. Choose the starting method by the load, and before any work isolate the supply, verify it is dead and have qualified electrical personnel carry it out.

222–232 A: cable, busbar and overload

The currents above are what each model draws at rated load on 400 V, and they exceed 220 A. At this level you talk about multiple parallel conductors or busbars rather than a single cable; the cross-section must be engineered for the current, run length and installation method. Undersizing brings heavy heating and voltage drop.

For a first estimate the motor current chart and cable size calculator help. Set the overload protection from the current on the motor plate and the panel documentation; do not rely on a fixed figure. Protection coordination and breaker/contactor sizing are a separate engineering task at this power.

315 frame dimensions, shaft and mounting

The shaft diameter varies with speed: 65×140 mm on the 3000 rpm model and a thicker 85×170 mm on the 1500 and 1000 rpm models (dia × length). The shaft diameter and keyway are critical for coupling, pulley and gearbox fits; the wrong shaft means you cannot mount it even if power and speed are right.

The IEC frame is 315M for 2 and 4 poles and 315L for 6 poles. Mounting can be foot B3, flange B5 or foot+flange B35; on a 315 frame the flange and shaft are clearly larger than on small frames, so always state the mounting type when ordering. The electric motor calculator also helps check fits.

Weight, handling and installation

A 315-frame electric motor, in cast iron, weighs several hundred kilos. This is the point most often overlooked when buying 132 kW, and the one that causes the most trouble. A forklift or crane, a sling matched to the lifting lug on the frame, and a mounting base with enough load capacity must all be ready before the motor arrives. Handling it by hand is both dangerous and impossible.

From our İzmir base we ship electric motors of this weight anywhere in Türkiye, that province included, with suitable palletising and fastening. When unpacking, check the shaft, terminal box and lifting lug for transport damage; clarifying the installation plan and lifting equipment before dispatch saves time on site.

132 kW DRG models

Below are three cast-iron 132 kW (180 HP) DRG models with speed, 400 V current and shaft size. Each code links to its product page.

ModelSpeedCurrent (400 V)Shaft
DRG-315M-2-GG3000 rpm (2 poles)222 A65×140 mm
DRG-315M-4-GG1500 rpm (4 poles)224 A85×170 mm
DRG-315L2-6-GG1000 rpm (6 poles)232 A85×170 mm

Clarify before ordering

At 132 kW a wrong choice is costly. Settle these before ordering: required speed (poles), starting method (soft starter, drive or star-delta), mounting type (B3/B5/B35), shaft diameter and the lifting capability on site. If you are replacing an existing electric motor, the safest step is to send a photo of the old nameplate so we can confirm frame and shaft fit together.

Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp

See the current price of the 132 kW electric motor by speed in the shop.SEE PRICES

Frequently asked questions

How many HP is 132 kW?

132 kW is about 180 HP (1 HP ≈ 0.746 kW). It is often searched as a "180 HP electric motor"; both describe the same power class.

Does a 132 kW electric motor run on 380 V?

Yes. The grid still called 380 V is now rated 400 V. A 132 kW model marked 400/690 V runs at full power in delta (Δ) on a 400 V supply.

Can I start it direct-on-line?

Not advisable. At 132 kW a soft starter or drive is used in most panels to limit inrush and mechanical shock; star-delta suits only light-starting loads. The final decision follows your panel design.

Which speed should I choose?

It depends on the machine: 3000 rpm for compressors and centrifugal pumps, 1500 rpm for general drive and gearboxes, 1000 rpm for slow, high-torque mills and crushers.

Electric Motors Related to This Topic — Models and Current Prices

Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.