If a quotation has no efficiency table, ask for the core data that identifies the motor exactly: rated power (kW and HP), speed and pole count, supply voltage and connection, rated current, frequency, IEC frame size, mounting type, protection rating, insulation class and duty type. Without these lines you cannot compare two offers fairly; request the efficiency figure separately, from the manufacturer's test and data sheet.

DRG three-phase asynchronous electric motor illustrating the power, speed and voltage data to request in an IE4 electric motor quote

DRG Motor is a manufacturer, supplier and seller of electric motors; it is based in İzmir and ships quickly across all of Türkiye, that province included. Once your requirement is clear, review the three-phase models that match power and speed in the online electric motor shop and see the same group together in the three-phase asynchronous electric motors category.

Why does the efficiency table go missing?

Not every seller sends the same paperwork. Some quotes show only power and price and skip the technical sheet. Sometimes the product is not catalogued yet, or whoever prepared the offer could not reach the data sheet. Whatever the reason, an incomplete document is not your problem to accept; asking the right question and getting it completed is in your hands. Even while you wait for the table, collecting the identity data below already tells you whether the offer fits the motor.

Core data to request in every quotation

On site, when someone says "just the same one", nobody reads the plate; yet those plate lines are what make a comparison fair. Before judging an offer, ask for all of this:

  • Rated power — in kW; most documents also give the HP equivalent (1 HP ≈ 0.746 kW).
  • Speed and poles — rated speed in rpm and the pole count (2, 4 or 6 poles).
  • Voltage and connection — 230/400 V or 400/690 V, with the star-delta wiring.
  • Rated current — in A; panel and overload selection sit on this value.
  • Frequency — in Hz; confirms it matches your supply.
  • IEC frame and mounting — frame code (e.g. 112M) with foot (B3) or flange (B5/B14) mounting.
  • Protection and insulation — IP rating and insulation class.
  • Duty type — the operating-regime code on the plate and the ambient temperature limit.

This list lets you compare offers with confidence before any efficiency figure arrives. Ask for the efficiency value as well, and use the remaining lines to confirm the offer suits your application.

Click to see current electric motor prices and order nowSEE PRICES →

A sample data table for comparison

Below are a few examples from the real DRG three-phase asynchronous range; when you assess an offer, ask the seller for exactly these columns. The figures are for 4-pole (1500 rpm) aluminium-frame models.

ModelPower (kW / HP)Speed (rpm)Voltage (V)
DRG-90L-41.5 / 21500230/400
DRG-112M-44 / 5.51500400/690
DRG-132S-45.5 / 7.51500400/690
DRG-132M-47.5 / 101500400/690
DRG-160M-411 / 151500400/690

Power and speed: the backbone of the offer

Two offers can print the same kW yet do a different job if the speed differs. Shaft torque depends on power and on speed: T = 9550 · P / n (P in kW, n in rpm, T in Nm). A lower-speed motor produces more torque than a higher-speed one at the same power. When you assess an offer, work from the speed and torque your machine needs; "the kW matches" is not enough on its own. Ask for the HP equivalent on the power line too, and you cut confusion from the start. To confirm the rated current you can check the values for each power on the motor current table.

Mounting, frame and connection

The second half of the core data concerns the mechanics. The IEC frame size (e.g. 90L, 112M, 132S) sets the shaft diameter, the foot holes and the flange dimension; the offer must give this code so you know it will fit. The mounting type must be clear too: foot (B3), flange (B5/B14) or foot-and-flange. On the electrical side the DRG aluminium range runs at 230/400 V up to 3 kW and 400/690 V from 4 kW; the connection (star-delta) should be stated in the offer. Record the protection rating and insulation class as well; in dusty or damp locations that line matters.

Comparing offers step by step

  1. Photograph the existing motor's plate; note power, speed, voltage, current and frame code.
  2. Ask each seller for the core data above in full and in writing.
  3. Request the efficiency value as a separate item, based on the manufacturer's data sheet.
  4. Put the offers in one table; if power, speed and voltage do not line up, the comparison misleads.
  5. Compare mounting and shaft size with the existing setup; a matching frame code makes the job easy.

Common mistakes

The most frequent mistake is looking only at power and price and skipping the speed; unexpected torque problems then appear at the coupling or pulley. The second is ordering without asking about voltage and connection. The third is deciding without stating the mounting type and ending up with a frame that will not fit. The fourth is postponing the whole comparison because the efficiency table did not arrive; with the core data in hand you can start assessing today.

Click to see the models and current prices of three-phase electric motors for your needSEE PRICES

Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp

Frequently asked questions

Can I order without an efficiency table in the quote?

If the core data (power, speed, voltage, current, mounting) is complete, you have identified the motor. Still ask for the efficiency value separately; having it in writing before you decide is the sound approach.

Which figure misleads most in a comparison?

Speed. The same kW at a different speed means different torque; two offers equal on power may not behave equally on your machine.

Why ask for the frame code separately?

The IEC frame size sets the shaft diameter, foot holes and flange. If the code does not match, the motor will not fit; the offer must state it clearly.

If I send the plate, can you find the right model?

Yes. Send a photo of the existing motor's plate; by power, speed, voltage and frame size we will determine the suitable DRG model together.

Electric Motors Related to This Topic — Models and Current Prices

Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.

ALL MODELS AND DETAILS IN THE ONLINE SHOP →