First, separate two things: when the same motor turns out different volumes in summer and winter, the total kWh at the panel also differs; that difference comes from the production swing, not from the motor. To compare two periods honestly in a saving project, do not compare total consumption but the energy per unit produced (kWh per piece, or kWh per tonne). Without this normalisation, saying "the bill dropped" or "it rose" is misleading.

Grey DRG three-phase electric motor illustrating correcting a seasonal production difference with per-unit energy

DRG Motor is a manufacturer, supplier and seller of electric motors. It is based in İzmir and ships quickly across all of Türkiye, that province included. Find the power your line needs by speed in the online electric motor shop and see the same models together in the three-phase asynchronous electric motors category.

Why does a seasonal production swing distort the comparison?

An electric motor draws energy in proportion to the work its machine does. In the busy season the line runs full all day; in the quiet season it turns at half load. Putting January's total kWh next to July's total kWh on such a line means weighing different volumes on the same scale. The number changes, but that change measures how many parts came out that month, not whether your saving measure worked. This is the most common field mistake: a new motor goes in, next month's bill falls, and everyone says "savings" — when production fell too.

The reverse happens as well. After the new motor, the season picks up, output rises, total kWh climbs, and the improvement looks like a loss. In both cases the fault is in the method, not the motor.

What is per-unit normalisation?

Normalisation means dividing consumption by output. You divide total kWh by the pieces produced that period (or tonnes, metres, m³ — whatever the line's natural unit is). The result is energy per unit: "how many kWh did one piece cost". Whatever the season, this ratio shows the real effect of your measure. If output doubles but energy per unit stays the same, the measure has made no difference yet; if the ratio falls, the gain is real.

The maths is simple: unit energy = period total kWh ÷ period output. Do it for before and after, then compare the two ratios. The summer-winter gap drops out of the equation.

Click to see current electric motor prices and order nowSEE PRICES →

How do you normalise, step by step?

  1. Pick the two periods to compare (e.g. the same month last year and this year); match the season.
  2. Read the total kWh the line drew for each period from the meter or panel analyser.
  3. Take the output in pieces (or tonnes) for the same periods from the production record.
  4. Divide kWh by pieces for each period to get the unit energy.
  5. Compare the two unit-energy values; talk about the before-after ratio rather than a percentage.

Where possible, measure only the line that motor feeds. Reading the whole factory's main meter lets lighting, compressors and heating — loads unrelated to production — pollute the result.

Example: same motor, two different seasons

Say a 1500 rpm three-phase motor drives a mixer. Suppose the readings over two periods are:

PeriodTotal energyOutputUnit energy
Busy season9,000 kWh30,000 pcs0.30 kWh/pc
Quiet season5,400 kWh18,000 pcs0.30 kWh/pc

Someone looking at total kWh would say "consumption fell by 3,600 kWh, there's a saving". Yet unit energy is 0.30 kWh/pc in both periods; nothing changed, just less was made. Only that last column tells you whether the saving measure actually worked.

Separate the non-production (base) load

Even when a line makes nothing, the idling motor, standby and cooling still draw power. That is the base load. In a seasonal comparison the base load stays constant, but because output changes, its share per unit shifts. For a sounder comparison, measure the period's base load (consumption during stopped hours), subtract it from the total, and divide the remaining "production energy" by the pieces. On small lines this split is not essential; on large, variable lines it makes a visible difference.

Which motors do you build the measurement around?

Tracking unit energy first needs a correctly sized motor; one that strains the machine or runs largely idle corrupts the numbers. A few common ratings from DRG's 1500 rpm aluminium three-phase range:

ModelPowerSpeedFrame
DRG-90L-41.5 kW1500 rpm90L
DRG-112M-44 kW1500 rpm112M
DRG-132S-45.5 kW1500 rpm132S
DRG-132M-47.5 kW1500 rpm132M
DRG-160M-411 kW1500 rpm160M

Choose power by the mechanical load the line needs; a sizing tool gives a rough start, but check the machine nameplate for the exact figure.

See current three-phase motor options at the right power for the line you will measureSEE PRICES

Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp

Common mistakes

First, comparing two months in different seasons directly. Second, reading the whole factory meter to judge one line's measure. Third, estimating output roughly; unit energy only means something with a solid production record. Fourth, deciding on a single week; keep the period to at least a month so stoppages and shift differences average out.

Frequently asked questions

What if my output is not counted in pieces?

Use the line's natural unit: tonnes, metres, litres, m³, whatever it is, and divide by that. What matters is using the same unit in both periods.

What if shift count changes rather than the season?

The logic is the same. You normalise by dividing total kWh by the hours worked or the pieces produced that period, so the changed running time also drops out.

Is the comparison invalid if I can't measure the base load?

No. If the base load is small and the output large, the unit-energy ratio is still reliable. If the base load is large, separating it clearly corrects the result.

Can normalisation show a saving without changing the motor?

Normalisation does not create savings; it measures the change correctly. Real gains need the right power, good maintenance and running matched to the load; normalisation shows whether those are working.

Electric Motors Related to This Topic — Models and Current Prices

Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.

ALL MODELS AND DETAILS IN THE ONLINE SHOP →