If every "2 kW electric motor" search brings you 2.2 kW models, there is a simple reason: the IEC power steps do not include a three-phase asynchronous motor rated at exactly 2 kW. The closest standard power to that value is 2.2 kW, so in practice a 2 kW need is met by a 2.2 kW three-phase asynchronous motor.
DRG Motor is a manufacturer, supplier and seller of electric motors. You can compare every 2.2 kW three-phase model by speed and housing in the online motor shop, and see the whole group together in the three-phase asynchronous electric motors category.
Is there a standard 2 kW power step?
Rated motor powers are not chosen freely; they follow internationally agreed steps. In the medium-power region these steps run 1.1 – 1.5 – 2.2 – 3 kW. In other words, the only intermediate step between 1.5 kW and 3 kW is 2.2 kW; there is no separate 2.0 kW rung. That is why a "2 kW motor" search always lands on 2.2 kW in real products.
The 0.2 kW gap works in your favour. A 2.2 kW motor comfortably covers a 2 kW load expectation and leaves a small margin for starting or short load peaks. So the answer to "isn't 2 kW enough?" is clear: choose 2.2 kW as the standard product.
2.2 kW three-phase asynchronous motor: DRG model table
In the DRG range 2.2 kW is offered in three speed classes (2, 4 and 6 poles) and two housing materials (aluminium and cast iron). The table below shows each model's pole/speed class, rated torque and rated current at 400 V; the model codes link straight to the product page. The voltage on all models is 230/400 V (Δ/Y).
| Model | Poles / Speed | Torque | Rated current (400 V) |
|---|---|---|---|
| DRG-90L-2-AL (aluminium) | 2-pole / 3000 rpm | 7.26 Nm | 4.35 A |
| DRG-100L1-4-AL (aluminium) | 4-pole / 1500 rpm | 14.5 Nm | 4.52 A |
| DRG-112M-6-AL (aluminium) | 6-pole / 1000 rpm | 22 Nm | 5.09 A |
| DRG-90L-2-GG (cast iron) | 2-pole / 3000 rpm | 7.26 Nm | 4.35 A |
| DRG-100L1-4-GG (cast iron) | 4-pole / 1500 rpm | 14.5 Nm | 4.52 A |
| DRG-112M-6-GG (cast iron) | 6-pole / 1000 rpm | 22 Nm | 5.09 A |
The torque values can also be checked with T = 9550 · P / n. At a fixed 2.2 kW, torque grows as speed falls: the roughly 7.3 Nm of the 2-pole 3000 rpm model rises to 22 Nm on the 6-pole 1000 rpm model. So the right 2.2 kW model is decided less by power than by the speed and torque you actually need.
Click to see current electric motor prices and order nowSEE PRICES →
Which speed class: 3000, 1500 or 1000 rpm?
The same 2.2 kW is produced at three speeds, because an application usually asks for a specific speed and torque:
- 2-pole (about 3000 rpm): high speed, low torque. Preferred for fast-rotating loads such as small centrifugal pumps and fans.
- 4-pole (about 1500 rpm): the most common medium speed. A balanced choice for conveyors, mixers and general drives.
- 6-pole (about 1000 rpm): low speed, high torque. Suited to heavy-starting or slow-turning mechanisms.
If you are replacing an existing motor, the safest route is to read the speed on its nameplate and keep the same pole count. To check the required power and current beforehand, use the electric motor calculator and the motor current chart.
Aluminium or cast iron housing?
In the 2.2 kW class each speed is available in both aluminium and cast iron. The electrical figures (power, speed, torque, current) are identical in both; the difference is mechanical:
- Aluminium housing: lighter, easier to carry and mount. Practical for light machines and frequently relocated assemblies. You can also see these on the aluminium housing motors page.
- Cast iron housing: heavier and more robust; preferred where vibration and mechanical stress are high.
The choice is about picking the housing that best fits the need; both deliver the same 2.2 kW performance.
How many horsepower (HP) is 2.2 kW?
Since 1 HP is about 0.746 kW, 2.2 kW corresponds to roughly 2.95 HP, which is rounded to 3 HP. So a user searching for a "2 kW motor" and one searching for a "3 HP motor" usually arrive at the same product: a 2.2 kW three-phase asynchronous motor. Product pages state the power in both kW and HP.
230/400 V wiring and safety
The 2.2 kW models are wound for 230/400 V (Δ/Y). On a 400 V three-phase supply the motor is connected in star (Y); on a 230 V three-phase supply it is connected in delta (Δ). The nameplate states which connection matches which voltage; always wire according to the nameplate and the panel documentation.
Before any electrical work, switch off the supply, confirm it is de-energised, and let only qualified electrical personnel make the connection. Set protection values such as the thermal current from the rated current on the nameplate, not from memory. For the cable cross-section, the motor cable size calculator is a helpful guide.
Shaft and mounting dimensions
The 2.2 kW motors come in different IEC frame sizes depending on speed class. In the table the 2-pole model sits in the 90L frame (24×50 mm shaft), the 4-pole model in the 100L frame and the 6-pole model in the 112M frame; the latter two have a 28×60 mm shaft. When replacing an old motor, compare not only the power but also the shaft diameter, foot/flange dimensions and mounting type (B3 foot, B5/B14 flange). Because couplings, pulleys and transmission parts are chosen by shaft diameter, this dimension is critical.
Send a photo of your current motor nameplate and we will find the suitable DRG model together.Send on WhatsApp
Once you have identified the right 2.2 kW model, you can compare all speed and housing options and current prices through the shop.
See the models and current prices of 2.2 kW and neighbouring three-phase asynchronous motors in the shopSEE PRICES
Frequently asked questions
Are a 2 kW motor and a 2.2 kW motor the same thing?
In practice, yes. Since 2 kW is not made as a standard product, the answer to a 2 kW need is a 2.2 kW three-phase asynchronous motor. The small difference causes no load problem and even leaves a small margin.
What is the rated current of a 2.2 kW motor?
At 400 V it is about 4.3–5.1 A depending on the model; always check the motor nameplate for the exact value. The table above gives the current of each 2.2 kW DRG model.
Which applications is a 2.2 kW motor suited to?
It depends on the speed class. 2 poles suit fast pumps and fans, 4 poles suit conveyors and general drives, and 6 poles suit slow, high-torque mechanisms. The best-fitting speed is usually read from the nameplate of the motor being replaced.
What should I choose if I need more power?
If 2.2 kW is not enough, the next step up is 3 kW. If you are unsure of your load calculation, clarify the nameplate data and operating conditions before comparing values with the shop models.
Electric Motors Related to This Topic — Models and Current Prices
Suitability is not decided by power alone: compare the speed, voltage, mounting, shaft and fixing dimensions of your machine with the product data; if unsure, send us the nameplate of your current motor.
2.2 kW Three-Phase Motor 3000 rpm – DRG-90L-2 Aluminium
- 2.2 kW · 3000 rpm (2 poles)
- Aluminium frame · IEC 90L
- Shaft: 24 × 50 mm
2.2 kW Three-Phase Motor 1500 rpm – DRG-100L1-4 Aluminium
- 2.2 kW · 1500 rpm (4 poles)
- Aluminium frame · IEC 100L
- Shaft: 28 × 60 mm
2.2 kW Three-Phase Motor 1000 rpm – DRG-112M-6 Aluminium
- 2.2 kW · 1000 rpm (6 poles)
- Aluminium frame · IEC 112M
- Shaft: 28 × 60 mm
2.2 kW Three-Phase Motor 3000 rpm – DRG-90L-2 Cast Iron
- 2.2 kW · 3000 rpm (2 poles)
- Cast iron frame · IEC 90L
- Shaft: 24 × 50 mm
2.2 kW Three-Phase Motor 1500 rpm – DRG-100L1-4 Cast Iron
- 2.2 kW · 1500 rpm (4 poles)
- Cast iron frame · IEC 100L
- Shaft: 28 × 60 mm
2.2 kW Three-Phase Motor 1000 rpm – DRG-112M-6 Cast Iron
- 2.2 kW · 1000 rpm (6 poles)
- Cast iron frame · IEC 112M
- Shaft: 28 × 60 mm